MecaIndus

Solenoid Valves

Solenoid valves are essential components within control and measurement systems for the automated management of fluids in industrial processes. These devices open or close the passage of liquids or gases in response to an electrical signal. Suitable for demanding environments, they ensure precise regulation within industrial valve installations, thereby guaranteeing the smooth running of technical operations whilst maintaining a high level of operational performance.

Marques disponibles en solenoid valves

Affichage 124 sur 8221 références

ASCO Electrovanne 3/2 serie 131
ASCO

13101183.24/DC

ASCO Electrovanne 3/2 serie 131

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 U G 1/4
ASCO

SCE370A026.24/DC

ASCO Electrovanne 3/2 U G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 NF G1/4
ASCO

12100310.48/DC

ASCO Electrovanne 3/2 NF G1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 NF G1/4
ASCO

12100314.24/DC

ASCO Electrovanne 3/2 NF G1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 NO G 1/4
ASCO

12100318.24/DC

ASCO Electrovanne 3/2 NO G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 2/2 NO G 1/4
ASCO

12100064.24/DC

ASCO Electrovanne 2/2 NO G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 NF G1/4
ASCO

12100128.48/50.612039

ASCO Electrovanne 3/2 NF G1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 NO G 1/4
ASCO

12100177.230/50

ASCO Electrovanne 3/2 NO G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO

12100202.24/DC.612039

ASCO Electrovanne 3/2 U G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO

12100202.48/DC.612039

ASCO Electrovanne 3/2 U G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 2/2 NF G 1/4
ASCO

12100222.230/50

ASCO Electrovanne 2/2 NF G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 2/2 NF G 1/4
ASCO

12100225.48/DC

ASCO Electrovanne 2/2 NF G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 NO G 1/4
ASCO

12100321.230/50

ASCO Electrovanne 3/2 NO G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 U G 1/4
ASCO

12100325.24/50

ASCO Electrovanne 3/2 U G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 U G 1/4
ASCO

12100329.230/50

ASCO Electrovanne 3/2 U G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 NO G 1/4
ASCO

12100354.230/50

ASCO Electrovanne 3/2 NO G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 NO G 1/4
ASCO

12100364.48/DC

ASCO Electrovanne 3/2 NO G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 U G 1/4
ASCO

12100348.48/DC

ASCO Electrovanne 3/2 U G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 U G 1/4
ASCO

12100349.48/50

ASCO Electrovanne 3/2 U G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO

12100951.230/50.612039

ASCO Electrovanne 3/2 NF G1/4

Sur devisRéponse sous 24 h ouvrées
ASCO Electrovanne 3/2 NF G1/4
ASCO

12100920.48/DC

ASCO Electrovanne 3/2 NF G1/4

Sur devisRéponse sous 24 h ouvrées
ASCO

13100017.230/50

ASCO Electrovanne 2/2 NF G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO

13100030.230/50

ASCO Electrovanne 2/2 NF G 1/4

Sur devisRéponse sous 24 h ouvrées
ASCO

13100075.230/50

ASCO Electrovanne 3/2 NF G1/4

Sur devisRéponse sous 24 h ouvrées

About Solenoid Valves

Within the scope of fluid management, solenoid valves act as indispensable electromagnetic actuators. These components integrate with control and measurement systems to drive the opening and closing of circuits, often as a complement to broader valve elements or specific connectors. The range available at MecaIndus brings together solutions from the ASCO, BURKERT, FESTO, PARKER and SECTORIEL catalogues, covering a diversity of technical configurations according to process requirements.

The selection of a solenoid valve must rely on several technical criteria that are decisive in ensuring the reliability of the installation. It is necessary to analyse the nature of the fluid, the service pressure, the electrical characteristics of the coil as well as the material of the valve body, which must offer optimal chemical compatibility with the conveyed fluid. The installation environment, including ambient temperature and mechanical constraints, also influences model selection. Particular attention must be paid to connection dimensions to guarantee the integrity of the joint within the existing pipework.

Integrating these components within an automated control architecture allows the flow rate and the sequence of streams to be optimised. The appropriate selection from the offerings of our partners enables a variety of applications to be addressed, ranging from the management of cooling circuits to industrial dosing systems. Each model must be sized taking into account the operating characteristics imposed by the final application to guarantee constant regulation and a rapid response during switching phases.

Frequently asked questions — Solenoid Valves